Drug Eluting Stent Injury Lawsuit. Boston Sceintific Taxus Stent - Johnson & Johnson Cypher Stent.
Ennis & Ennis, P.A. is also currently handling lawsuits for the following drugs: Accutane, Actiq, Adderall, Avandia, Bextra, Celebrex, Fosamax, Ketek, Ortho Evra Birth Control Patch, Paxil, Plavix, Seroquel, SJS, Tequin, Trasylol, Viagra, Vioxx, Zelnorm & Zyprexa.
 
Stent Recall
Drug Eluting Stents Lawsuit
Offices

Ennis & Ennis is dedicated to helping victims of defective and recalled traditional stents as well as the newer drug eluting stents throughout the country. If you or a loved one have been injured as a result of stent malfunction you may be entitled to compensation. For more information about your legal rights or to find out the latest recall information or for a free legal consultation contact our stent injury attorneys today.

 

 

 

 

 

Super-Thin Drug-Free Coating 'Hides' Stent as It Unblocks Heart Arteries

PR-USA.net

01/22/2008 - A new stent with a nanothin surface application shows promise in opening and healing blocked heart arteries without the life-threatening dangers of drug-eluting stents, according to a study being presented at the 20th annual International Symposium on Endovascular Therapy (ISET).


The stent coating is 25,000 times thinner than a human hair. Called Polyzene(R)-F, the treatment is not a drug but a medically inert chemical compound that "hides" the stent from the body.


Doctors have long used stents to open up plaque-clogged arteries in the heart and elsewhere in the body, but the vessels often reclog due to the body's reaction to the stent as a foreign object, which creates a scarring process known as restenosis. Drug-eluting stents were devised as an answer to restenosis, but research has shown the drug can interfere with the blood vessel's healing process. This increases the risk of blood clots forming (thrombosis) and causing a heart attack. Although studies suggest thrombosis occurs in less than 1 percent of patients who receive drug-eluting stents, it is fatal in nearly half of patients who develop the problem.


"Our preliminary data show that the inside of the blood vessel with this polymer-coated stent heals almost perfectly within 30 days, whereas with a drug-eluting stent, the blood vessel healing takes many months, if it ever happens," said Corrado Tamburino, M.D., Ph.D., principal investigator of the study and professor of cardiology at Ferrarotto Hospital at the University of Catania, Italy. "Our preliminary research suggests that this polymer-coated stent is a very promising solution to restenosis and thrombosis."


Results of the first use of this coated stent in humans are being presented at ISET. In the Assessment of the Latest Non-Thrombogenic Angioplasty (ATLANTA) Stent Study at the University of Catania, 55 patients received the new surface-treated stent to open up blockages in their coronary arteries, and six-month follow-up information is available for 40 patients. Six months after implantation, the patients were studied using angiography and intravascular ultrasound (IVUS). To date, none of the stents has developed thrombosis and the binary restenosis rate is below 10 percent.


An independent laboratory also used a diagnostic test called optical coherence tomography (OCT), which images the vessels at the cellular level. Performed at the time of the initial procedure and six months after implantation of the coated stent in 15 people (27 percent), OCT results suggest that the Polyzene-F promotes healing, rather than prompting scarring.


Blocked heart arteries have long been treated through open-heart surgery by bypassing the blockage with a new conduit (coronary artery bypass surgery). Minimally invasive repair of blocked arteries in the heart and elsewherein the body began more than 25 years ago with the advent of angioplasty.

Angioplasty involves making a nick in the groin and advancing a thin tube, or catheter, through the artery to the site of the blockage and inflating a tiny balloon to open up the vessel. It was much less invasive than surgery; however, in about half the cases, the artery would reclog, according to studies. In the mid-1990s, doctors began inserting a tiny metal cage, or stent, to keep the artery propped open, and the restenosis rate dropped to about 30 percent, studies found. Four years ago, doctors began using drug-eluting stents, devices coated with a chemotherapeutic agent, dropping restenosis rates to as low as 5 percent to 7 percent in some cases, according to studies.

It has since been discovered that potentially deadly clots that can form inside the drug-eluting stent, which researchers estimate kill 1,000 or more people every year. To combat the blood-clotting problem, medical experts recommend patients who receive drug-eluting stents be placed on dual anti-platelet therapy for at least one year. Dual antiplatelet therapy typically includes aspirin and the drug clopidogrel.


In the ATLANTA study, the clopidogrel was discontinued in all patients after 30 days, with no ill effects.


"Although antiplatelet therapy delays the problem of thrombosis in drug-eluting stents, when the therapy is stopped, the problem returns," said Dr. Tamburino. "However, continuing on antiplatelet therapy indefinitely is problematic, too, because it increases the risk of bleeding, and may prevent future surgeries."


The new surface-treated stent was designed to provide an answer to that problem. The stent is made of cobalt chromium and uses a modified open-cell design. The stent is coated with poly[bis(trifluroexthoxy)phosphazene], or Polyzene-F. The surface treatment is approximately 40 nanometers thick, too thin to be seen with a traditional microscope. The antithrombotic, bacterial-resistant coating essentially hides the stent so that the body doesn't react to the device as a foreign object as is the case for bare-metal stents. This, in turn, promotes the healing process so that the stent is incorporated into the body more naturally, preventing the formation of blood clots. After implantation of a traditional stent, the body essentially overreacts to the device, causing the scarring that leads to restenosis.


Polyzene-F was discovered by a group of scientists and has been used in humans for several years to coat tiny particles that embolize (block) arteries and treat a number of conditions, including liver cancer, uterine fibroids and malformed arteries. It's also been tested or is in testing on dental implants, orthopedic implants, breast implants and catheters. Because it is a coating, like Teflon(R) or silicone, it can coat, or be woven or spun onto metals, ceramics and other polymers to improve their performance. Fifteen times slicker than Teflon, Polyzene-F also has applications for aerospace, water treatment, textiles and various military uses.


Considered to be the premier meeting on endovascular therapy, the International Symposium on Endovascular Therapy (ISET) is attended by more than 1,200 physicians, scientists and industry professionals from around the world. The meeting pioneered the use of live cases to promote the multidisciplinary treatment of vascular disease. ISET is presented by the Baptist Cardiac & Vascular Institute, Miami.


If you or a loved one have been injured during surgical placement of a stent or have been injured as a result of an implanted drug eluting stent (drug coated stent) such as the Boston Scientific Taxus stent or the Johnson & Johnson Cypher stent you may be entitled to compensation. To learn more about the stent recalls, for information regarding your legal rights, or the possiblilty of a class action lawsuit contact our stent lawyers for a free, confidential, case evaluation today. Fill out our online case evaluation form or call us toll free at 1-800-856-6405.


Washington DC Office
1101 Pennsylvania Ave.
Suite 600
Washington DC 20004
Telephone: 202-756-2972

Miami Office
1111 Brickell Avenue
11th Floor
Miami, FL 33131
Telephone: 305-913-7199

Fort Lauderdale Office
110 E. Broward Blvd.
Suite 1700
Fort Lauderdale, FL 33301
Telephone: 954-315-3934
Facsimile: 954-315-3914


Free Case Evaluation. Nationwide: 1-800-856-6405